Custom models • Interpretable SAR • Analogue design

Custom QSAR Modeling
& Lead Optimization

Turn your molecular structures and experimental activities into an interpretable model, a prioritized compound series, and a focused plan for the next round of chemistry.

2D & 3D QSAR CoMFA & CoMSIA SAR-guided design

Start with your structure–activity data

Understand what drives activity. Choose what to make next.

A compound series often contains more information than a list of assay values reveals. Which substitutions consistently improve activity? Where does extra steric bulk help? Which untested analogues deserve synthesis? Our custom QSAR service connects measured responses with chemical features to answer these questions in a project-specific workflow.

01 / EXPLAIN

Interpret an existing series

Compare analogues, identify influential molecular features, and relate activity differences to a consistent chemical representation. Receive an organized SAR narrative supported by model diagnostics and visual analysis.

02 / PRIORITIZE

Rank untested compounds

Apply the resulting model to proposed analogues or a focused library. Receive numerical predictions, applicability annotations, and a shortlist aligned with your available assay capacity.

03 / DESIGN

Explore new analogues

Translate model interpretation into substituent ideas and new structures around your retained scaffold. Compare predicted activity trends alongside chemistry constraints and development priorities.

Looking for prediction without commissioning a new model? Explore our QSAR-based virtual screening and activity prediction service within the wider QSAR service portfolio.

Project preparation

What should you provide for custom modeling?

Start with a compound table that links every structure to a stable identifier and an experimentally measured endpoint. Assay provenance matters as much as the activity value: it determines which records can be interpreted together and which require separate analysis.

Input What to include How it supports the analysis
Compound structures SMILES, SDF, or MOL2; compound identifiers; explicit stereochemistry; salt or parent-form information. Establishes a consistent chemical dataset for descriptor generation, conformer preparation, and analogue comparison.
Experimental activity Endpoint such as IC50, EC50, Ki, or Kd; units; exact values or inequality qualifiers; replicate information. Defines the response being modeled and supports appropriate transformation and handling of censored measurements.
Assay context Target, subtype and species; biochemical or cellular assay; assay conditions; source or batch; measurement date where available. Supports assay harmonization, endpoint selection, study grouping, and a validation strategy matched to the intended application.
Prediction set Untested analogue structures, reference compounds, library size, and the number of candidates you plan to test. Connects model development with an actionable ranking and selection task.
Design constraints Retained core, permitted modification sites, excluded groups, property objectives, and synthesis preferences. Focuses new-structure proposals on chemistry your team can pursue.
Optional structural evidence Protein–ligand complexes, binding-site information, reference poses, or a known pharmacophore. Enables receptor-guided alignment and complements ligand-based SAR interpretation.

A useful first email: tell us the target, assay endpoint, number of measured compounds, structure format, activity range, and whether you need explanation, prediction, or design. Share a data overview through the inquiry form for initial project feedback within 24 hours.

Choose the representation around the question

2D-QSAR, CoMFA, and CoMSIA in one modeling strategy

QSAR is a quantitative relationship between molecular representation and an experimental response. We select the representation to match the chemical series and intended decision. A 2D baseline provides a useful comparator; a field-based 3D model adds spatial interpretation around consistently aligned conformations.

Approach Representation Best suited to Interpretation delivered
2D-QSAR Physicochemical descriptors, molecular fingerprints, and structural features. Baseline prediction, broader compound collections, and feature-based comparison. Descriptor contributions or feature attribution using an explanation method appropriate to the selected model.
CoMFA Steric and electrostatic interaction fields around aligned molecular conformers. Related analogues with a meaningful common alignment and a need for spatial SAR interpretation. Field contours showing regions associated with favorable and unfavorable changes.
CoMSIA Similarity-based fields selected from steric, electrostatic, hydrophobic, and hydrogen-bond features. Exploring how complementary field combinations explain a defined chemical series. Spatial interpretation of the selected fields together with quantitative model evaluation.

For a continuous endpoint, we compare regression models using errors and predictive performance on the selected evaluation sets. For an activity-threshold decision, classification or enrichment analysis may be appropriate. Model choice follows the experimental question, data coverage, and validation outcome rather than a fixed software label.

Three-dimensional preparation

Make alignment a deliberate modeling choice

Field-based QSAR compares molecules in a common spatial frame. Conformer generation, protonation, stereochemistry, and alignment therefore receive explicit attention. Depending on available evidence, alignment can follow a conserved scaffold, a shared pharmacophore, or a receptor-supported binding pose.

We examine alternative preparation and alignment strategies during model development and retain the chosen procedure in the project record. This allows the same preparation logic to be applied when new structures enter the prediction workflow.

If you have a protein structure and need a binding-mode explanation, molecular docking for SAR interpretation can connect the ligand-based model with pocket interactions. Ligand-only projects can proceed from chemical structures and measured activity.

Published molecular superposition used to align a triazolopyrazine compound series for field-based QSAR
Published molecular alignment of a triazolopyrazine series using a reference compound as the template.

Integrated workflow

Six stages from measured data to optimization priorities

01 / SCOPE

Define the endpoint

Activities: confirm assay, species, chemical scope, and intended prediction or design task.

Decision output: an agreed modeling objective and evaluation plan.

02 / CURATE

Audit structures and values

Activities: standardize structures, review duplicates, units, qualifiers, and assay consistency.

Decision output: a documented modeling dataset and record of data decisions.

03 / REPRESENT

Prepare descriptors and fields

Activities: compute selected 2D features, generate conformers, and develop alignment strategies for 3D analysis.

Decision output: reproducible molecular representations.

04 / MODEL

Train and evaluate

Activities: compare models, select complexity, perform validation, and examine applicability.

Decision output: selected models with task-relevant performance evidence.

05 / INTERPRET

Translate results into SAR

Activities: compare analogues, inspect field contours, review influential compounds, and predict new structures.

Decision output: ranked candidates and structural hypotheses.

06 / DESIGN & REPORT

Plan the next chemistry cycle

Activities: prioritize modifications, prepare deliverables, and incorporate the next round of experimental results.

Decision output: a traceable report and actionable optimization plan.

Evaluation designed for the decision

Measure prediction performance beyond the fitted dataset

Validation is planned around the compounds the model will encounter. For a continuing medicinal-chemistry series, a chronological assessment can approximate prediction of later compounds. For chemically distinct candidates, grouping by scaffold or similarity helps examine transfer across chemical space.

Independent evaluation

Define the test set before model selection. Conduct feature selection, scaling, alignment-strategy selection, and hyperparameter tuning within the training and validation process, keeping the final test compounds outside those decisions.

Task-specific metrics

For regression, report measures such as MAE, RMSE, test-set R², and cross-validation statistics with their definitions. For prioritization, examine ranking or enrichment against the selection objective. Summarize residual patterns and difficult compounds.

Chemical coverage

Use an applicability assessment suited to the model representation, such as structural similarity, descriptor-space distance, or leverage diagnostics. Attach compound-level annotations so the prediction table carries its chemical context.

Robustness and updating

Where data support it, use repeated splits, response permutation, and baseline comparison to examine sensitivity and chance correlation. Retain new measurements for prospective assessment and planned model updates.

From interpretation to design

Turn model insights into a focused analogue set

Design begins with the retained scaffold and the modifications your chemistry team can explore. We translate field interpretation and analogue comparisons into specific substitution directions, then generate and score candidate structures within those constraints.

A useful design set balances predicted activity with chemical diversity and project preferences. Instead of returning many nearly identical top-scoring structures, the selection can cover distinct substitution ideas and include compounds that help clarify an uncertain SAR trend.

For multi-parameter optimization, connect activity modeling with in silico ADMET assessment to compare the property trade-offs relevant to your program. Synthesis and assay planning can then focus on the most informative next compounds.

Design brief: specify the retained core, editable sites, excluded motifs, preferred building blocks, and the number of structures you want to advance. The output is a structure list with a clear rationale for each selected direction.

Schematic illustration of related molecular analogues with a conserved scaffold and different peripheral substitutions
Schematic illustration of analogue design around a retained molecular core.

Published application

See how molecular fields guide structural hypotheses

Published CoMFA electrostatic and steric contour maps around a triazolopyrazine reference compound
Electrostatic and steric CoMFA contours around a reference triazolopyrazine compound in a published study.

Spatial SAR that informs analogue choices

A published triazolopyrazine study combined molecular alignment, CoMFA/CoMSIA modeling, contour interpretation, and computational analogue design. It illustrates the connection between an experimentally characterized series and proposed structural modifications.

In a custom project, the field maps are interpreted alongside your assay records and the specific compounds that support each trend. The resulting recommendations identify where to explore steric, electrostatic, hydrophobic, or hydrogen-bond changes, according to the selected model.

We package this reasoning with numerical evaluation and candidate structures so a medicinal chemist can connect the recommendation to an actual synthesis or assay decision.

Deliverables

A modeling package built for chemistry and assay teams

The project report connects every major conclusion to compound identifiers, data preparation decisions, and model results. Select a modeling-only package or extend it with candidate prediction, analogue design, and a subsequent experimental feedback cycle.

✓

Curated structure–activity dataset

Standardized structures, endpoint definitions, units or transformations, dataset partitions, and a record of excluded or separately analyzed measurements.

✓

Model development and evaluation

Methods, preparation workflow, selected features or fields, model-comparison results, validation metrics, and reproducibility information.

✓

SAR interpretation and visuals

Compound comparisons, selected molecular-field maps, influential structural features, and a coherent explanation of the observed activity trends.

✓

Predictions and candidate ranking

Compound-level outputs, explicit endpoint scale, applicability annotations, and a prioritized list suited to your next assay or purchasing round.

✓

Optional analogue-design set

Proposed structures in a convenient chemical format, modification rationale, comparative predictions, and a shortlist reflecting design constraints.

✓

Technical review and next-step plan

A results discussion, recommended experimental comparisons, and a plan for incorporating new measurements into the next model update.

Project questions

Prepare your custom QSAR study

How many compounds are needed?

Feasibility depends on chemical diversity, activity range, assay quality, and model complexity. Share the full dataset overview first. We assess whether it supports quantitative modeling, a simpler baseline, or an initial exploratory SAR study.

Can different activity measurements be combined?

Compatible records can be harmonized after reviewing units, assay format, target context, and qualifiers. IC50, Ki, binding affinity, and cellular response retain separate endpoint definitions; conversion or pooling requires a justified experimental basis.

Can you model selectivity?

Yes, when matched measurements exist for the relevant targets or subtypes. A selectivity project can compare endpoint-specific models or model a clearly defined selectivity measure using compatible assay data.

Is a protein structure required for 3D-QSAR?

Ligand-based approaches can use chemical structures and activity values. A relevant protein–ligand complex can add binding-pose evidence for alignment and interpretation when the project calls for a receptor-guided analysis.

Can you predict compounds after the model is built?

Yes. A follow-on prediction package applies the retained preparation and model workflow to new structures. When the task becomes a larger library selection, continue through QSAR-based virtual screening.

What should I send to obtain a proposal?

Provide the target, endpoint, measured compound count, structure format, assay background, and your desired output. Include prediction-set size or analogue-design constraints where relevant. Initial project feedback is available within 24 hours.

Make your next chemistry round more informative

Bring your structures, experimental activities, and design priorities. We will shape a custom modeling and optimization plan around the decisions your team needs to make.

Discuss Custom QSAR Modeling →

Scientific References

  1. Baammi, S.; El Allali, A.; Daoud, R. Potent VEGFR-2 inhibitors for resistant breast cancer: a comprehensive 3D-QSAR, ADMET, molecular docking and MMPBSA calculation on triazolopyrazine derivatives. Frontiers in Molecular Biosciences 2023, 10, 1288652. doi:10.3389/fmolb.2023.1288652. Figures 1 and 5 reproduced under CC BY 4.0.
  2. Sheridan, R. P. Time-split cross-validation as a method for estimating the goodness of prospective prediction. Journal of Chemical Information and Modeling 2013, 53, 783–790. doi:10.1021/ci400084k.
  3. Tropsha, A. Best practices for QSAR model development, validation, and exploitation. Molecular Informatics 2010, 29, 476–488. doi:10.1002/minf.201000061.
  4. Ragno, R. www.3d-qsar.com: a web portal that brings 3-D QSAR to all electronic devices—the Py-CoMFA web application as tool to build models from pre-aligned datasets. Journal of Computer-Aided Molecular Design 2019, 33, 855–864. doi:10.1007/s10822-019-00231-x.

Online Inquiry

Submit your project details below, and our team will respond within 24 hours.

x
Need help getting the data you need?

Talk to our technical team about your project!

I Want To Talk