QSAR • Molecular Prediction • Decision Support

QSAR Modeling &
Molecular Prediction Services

Send compound structures and an assay endpoint to rank candidates for testing. With measured activities, we can also build a custom QSAR model and identify substitutions for your next analogue series. For process impurities, request a separate mutagenicity evidence report.

Custom 2D & 3D QSAR Target-specific prediction Impurity assessment

Three ways to start

Choose the route that fits your molecular question

Choose custom modeling to interpret measured activity, screening to select compounds for an assay, or impurity assessment to review a potential mutagenicity concern.

01 / BUILD & OPTIMIZE

Custom QSAR Modeling & Lead Optimization

Turn your structure–activity dataset into a quantitative explanation of potency differences and a practical guide for the next round of chemistry.

You provide
Molecular structures, measured activities, assay information, and design priorities.
We deliver
Model evaluation, SAR interpretation, and candidate predictions. An aligned 3D analysis can also include molecular-field maps.
Explore 3D-QSAR modeling services →
02 / PREDICT & PRIORITIZE

QSAR-Based Screening & Activity Prediction

Evaluate new structures against a defined biological endpoint and focus your experimental budget on a ranked, chemically meaningful shortlist.

You provide
A compound collection, target or endpoint, and selection criteria.
We deliver
Compound-level predictions, model applicability analysis, ranking, and a focused list for purchase, synthesis, or testing.
Explore prediction and screening →
03 / ASSESS & DOCUMENT

Impurity Mutagenicity & Regulatory Support

Connect impurity structures with computational evidence and expert interpretation to support development-stage safety assessment.

You provide
Impurity identities, process or degradation context, available studies, and the assessment objective.
We deliver
Complementary prediction results, expert review, evidence tables, and a structured technical assessment.
Explore ICH M7 impurity assessment →

Target-specific prediction products

Start with a focused molecular prediction task

Choose ERα or CB1 to compare receptor binding affinity, or uPA to compare enzyme inhibition. Include the assay readout used for your reference compounds so that the ranking answers the same experimental question.

Rainbow ribbon representation of the human ERα ligand-binding domain, PDB 1A52
UniProt P03372 · PDB 1A52 · ligand-binding domain
NUCLEAR RECEPTOR / ERα

ERα Ligand Binding Affinity Prediction

Compare estrogen receptor ligands, prioritize analogues, and examine the structural features associated with stronger binding. Include reference ligands with measured affinity to anchor comparisons within your series.

Input
SMILES or SDF structures and the compound comparison objective.
Output
Affinity estimates, ranked ligands, chemical-series comparison, and interpretation.
View ERα Prediction Service →
Rainbow ribbon representation of the human CB1 receptor region, PDB 5TGZ
UniProt P21554 · PDB 5TGZ · receptor region
GPCR / CANNABINOID RECEPTOR

CB1 Receptor Ligand Affinity Prediction

Screen a focused ligand collection and compare binding-affinity trends within the CB1 chemical space. For competition-binding data, include the radioligand and reported Ki units. Functional agonist potency requires a separately defined assay endpoint.

Input
Candidate structures, reference ligands, and the desired binding endpoint.
Output
Affinity-based prioritization, analogue comparison, and an experimental shortlist.
View CB1 Prediction Service →
Rainbow ribbon representation of the human uPA catalytic domain, PDB 1OWD
UniProt P00749 · PDB 1OWD · catalytic domain
SERINE PROTEASE / UPA

uPA Inhibitor Activity Prediction

Prioritize urokinase-type plasminogen activator inhibitors and compare substitution strategies. Include the substrate and assay conditions when comparing IC50 measurements across inhibitor series.

Input
Inhibitor structures, activity endpoint, and chemical-series information.
Output
Activity estimates, ranked candidates, SAR interpretation, and optimization priorities.
View uPA Prediction Service →

Space-filling views show chain A of each experimental structure. Orange marks exposed ligand atoms. Estradiol is buried within the ERα domain. The CB1 view excludes the crystallization fusion.

Match your starting point

What do you have, and what do you need?

Define the endpoint before choosing the method. Receptor binding, enzyme inhibition, cellular response, and bacterial mutagenicity answer different questions. A project brief that names the endpoint, chemical series, and next decision helps us build a focused analytical package.

Your starting point Recommended route What you receive Decision supported
A measured series of compounds with unexplained activity differences Custom 2D/3D-QSAR modeling Curated dataset, evaluated model, SAR interpretation, field maps Which structural changes should the next design round explore?
A new set of analogues or a focused compound library Target-specific prediction and screening Prediction table, applicability assessment, ranked shortlist Which molecules should be tested, purchased, or synthesized first?
A lead structure and a defined modification space QSAR-guided analogue design Proposed structures, predicted trends, substitution priorities Which modifications best address the selected activity objective?
Process impurities or degradation products needing safety assessment Impurity mutagenicity assessment Prediction evidence, expert interpretation, assessment report How should the impurity evidence and follow-up work be organized?
An existing model plus newly measured compounds Model validation and update Independent performance analysis, revised scope, updated prediction workflow How well does the model support the current chemical series?

Understand the chemistry

From molecular fields to the next compound design

QSAR links chemical structure to a measured response. Two-dimensional approaches use features such as molecular descriptors and fingerprints; three-dimensional approaches examine spatial properties around aligned conformations. CoMFA emphasizes steric and electrostatic fields, while CoMSIA can incorporate additional hydrophobic and hydrogen-bonding features.

These analyses can make a series easier to interpret. Field contours highlight regions associated with favorable or unfavorable substitutions, while numerical predictions help compare proposed analogues. The combination turns a broad question—what should we change?—into a focused set of medicinal-chemistry hypotheses.

When binding-mode information is important, molecular docking for SAR interpretation adds a complementary view of pocket contacts. For a broader library search, our virtual screening services connect compound prioritization with structure- and ligand-based selection.

Bring the design constraints. Share the scaffold you want to retain, positions open to substitution, reference compounds, and the number of molecules your next assay can accommodate.

Schematic illustration linking aligned molecular conformers, interaction fields, and compound prioritization
Schematic illustration: molecular representation, field interpretation, and compound prioritization.

Project workflow

A clear route from project brief to decision

We organize the analysis around a specific outcome: explain an existing series, select the next assay set, propose analogues, or document impurity evidence. The same endpoint and compound identifiers remain connected throughout preparation, analysis, and reporting.

01 / DEFINE Scope the question

Confirm target, endpoint, units, assay context, compound count, and intended use. For regulatory-support work, define the impurity context and documentation objective.

02 / PREPARE Organize the chemistry

Review structures, stereochemistry, salts, duplicate records, and activity transformations. For 3D workflows, generate conformers and establish a consistent alignment strategy.

03 / ANALYZE Model or predict

Develop and evaluate a custom model, apply a target-focused workflow, or assemble complementary mutagenicity predictions. Connect outputs with chemical context and reference evidence.

04 / DECIDE Deliver the next action

Provide traceable tables, interpretation, and a prioritized next step. New assay results can feed back into model refinement and the following design cycle.

Decision-ready deliverables

Receive results your team can use

Choose the reporting depth that matches your project, from a focused prediction package to a complete model-development study or expert-reviewed impurity assessment. Deliverables are organized by compound identifier so results remain easy to compare with chemistry and assay records.

✓

Compound-level results

Machine-readable tables connect each submitted structure to its predicted endpoint, unit or transformed scale, ranking, and analytical annotations.

✓

Prioritized testing shortlist

A focused selection combines predicted activity with chemical-series coverage and project criteria, supporting a manageable next assay set.

✓

Model evaluation package

The report identifies the training and validation compounds, error metric, and chemical series represented. If independent measurements are available, it also reports held-out performance.

✓

Interpretable SAR visuals

Aligned structures, molecular-field contours, and analogue comparisons connect numerical results with actionable structural features.

✓

Optimization proposals

Design-focused packages provide proposed structures, modification rationale, predicted trends, and priorities for synthesis planning.

✓

Expert-reviewed evidence report

Safety-assessment packages combine prediction records, reference evidence, expert interpretation, and a structured account of follow-up priorities.

Reading the results

Which compounds belong in the next assay?

Read the endpoint, chemical coverage and ranking together. The following examples show how to use a prediction table when selecting a limited number of compounds for testing.

What the report shows How to use it
Two analogues have similar predicted affinity and their difference is smaller than the model’s typical prediction error. Treat them as comparable. Use synthesis feasibility or a second property to choose between them.
A highly ranked candidate has a scaffold poorly represented in the modeling set. Consider it an exploratory assay slot and include a supported reference compound in the same run.
New measurements come from a functional assay while the model predicts binding affinity. Keep the readouts in separate columns. Compare binding predictions against binding measurements and use the functional data to assess response.

Safety evidence & development

Connect impurity predictions with expert assessment

Impurity assessment starts with chemical identity and the development question. For ICH M7-oriented bacterial mutagenicity assessment, complementary expert-rule-based and statistical (Q)SAR methodologies form an established computational evidence route, with expert review used to interpret results.

Our impurity-assessment pathway brings structures, prediction evidence, study records, and expert reasoning into a consistent report. This helps teams organize the evidence, identify the questions that need additional work, and prepare focused supporting documentation.

Explore impurity mutagenicity assessment →

Expand the assessment around the liability

Early discovery programs may also need solubility, permeability, metabolism, cardiac-liability, or off-target information. Our in silico ADMET prediction service connects these endpoints with candidate selection and assay planning.

For medicinal-chemistry programs, activity predictions can be considered together with developability priorities. Share the property or safety concern that is driving your decision so the analytical scope addresses the actual trade-off.

Prepare an impurity brief: include structures or identifiers, process or degradation origin, available experimental findings, and the purpose of the assessment.

Common project questions

Plan your QSAR project

Do I need measured activity data?

Custom modeling begins with a structure–activity dataset and assay context. For a target-specific prediction project, start with your new structures and target endpoint; the scope is then matched to the chemical series and prediction task.

Do you need a protein structure?

Ligand-based QSAR can start from compound structures and activity measurements. Protein structures are useful for receptor-guided alignment, docking, and interpretation of the molecular features that distinguish active analogues.

Can the project include new molecule design?

Yes. A design package can extend the analysis into analogue enumeration, substituent proposals, candidate prediction, and synthesis priorities. Provide the retained scaffold, allowed modifications, and desired balance of activity and molecular properties.

Which structure formats should I send?

SMILES and SDF are convenient starting formats. Include stable compound identifiers, explicit stereochemistry, measured values and units where available, and a description of the assay or prediction objective.

Can you evaluate an existing model?

Model-review projects can examine the saved model, training records, preparation workflow, and independent data. The output connects performance and chemical coverage to the decisions your current compounds require.

How do I request a project scope?

Send your target or endpoint, approximate compound count, current data format, and intended decision. Our team provides initial project feedback within 24 hours and identifies the information needed for a focused proposal.

Bring your structures. Define the next decision.

For a quote, send the target, compound count, SMILES or SDF file, and the decision you need to make. For custom modeling, include an activity table with compound IDs, assay conditions, units, and qualifiers such as > or <.

Start Your QSAR Project →

Scientific References & Structure Sources

  1. Salum, L. B.; Polikarpov, I.; Andricopulo, A. D. Structural and chemical basis for enhanced affinity and potency for a large series of estrogen receptor ligands: 2D and 3D QSAR studies. Journal of Molecular Graphics and Modelling 2007, 26, 434–442. doi:10.1016/j.jmgm.2007.02.001.
  2. Shim, J. Y.; Collantes, E. R.; Welsh, W. J.; et al. Three-dimensional quantitative structure-activity relationship study of the cannabimimetic (aminoalkyl)indoles using comparative molecular field analysis. Journal of Medicinal Chemistry 1998, 41, 4521–4532. doi:10.1021/jm980305c.
  3. Insight into the structural requirements of urokinase-type plasminogen activator inhibitors based on 3D QSAR CoMFA/CoMSIA models. Journal of Medicinal Chemistry 2006. doi:10.1021/jm050149r. PMID:16420035.
  4. International Council for Harmonisation. M7(R2): Assessment and Control of DNA Reactive (Mutagenic) Impurities in Pharmaceuticals to Limit Potential Carcinogenic Risk. 2023. FDA guidance document.
  5. Structural coordinate sources: PDB 1A52, ERα ligand-binding domain with estradiol, UniProt P03372; PDB 5TGZ, CB1 receptor with AM6538, UniProt P21554, receptor residues shown without the crystallization fusion; PDB 1OWD, uPA catalytic domain with inhibitor, UniProt P00749. Product card images are original ribbon renderings of chain A from these deposited coordinates.

Online Inquiry

Submit your project details below, and our team will respond within 24 hours.

x
Need help getting the data you need?

Talk to our technical team about your project!

I Want To Talk